首页 /研究 /Precision X-Y robotic object handling using a dual GMR bridge sensor
OTHER

Precision X-Y robotic object handling using a dual GMR bridge sensor

Wanjun Ku, P. P. Freitas, P. Compadrinho, José Barata

发表年份
2000
引用次数
11

摘要

A dual integrated GMR bridge sensor, which is able to simultaneously detect x and y components of an external magnetic field, was demonstrated, and applied to the precision robotic placement of objects. Two orthogonal GMR bridges are used, biased by two sets of integrated Co/sub 78/Pt/sub 22/ film permanent magnets with different coercivities (1230 Oe and 522 Oe, respectively). The field sensitivity is 0.35 mV/(V/spl times/Oe) in each field direction. For the positioning application, an absolute accuracy of 10 /spl mu/m in x-direction has been achieved over more than 1900 cycles which is insensitive to sensor offsets and thermal drifts.

关键词

MagnetSensitivity (control systems)Magnetic fieldMaterials scienceDual (grammatical number)PhysicsNuclear magnetic resonanceComputer scienceElectronic engineeringEngineering