首页 /研究 /Issues in impedance selection and input devices for multijoint powered orthotics
OTHER

Issues in impedance selection and input devices for multijoint powered orthotics

Michel Lemay, Neville Hogan, J.W. Arian van Dorsten

发表年份
1998
引用次数
31

摘要

We investigated the applicability of impedance controllers to robotic orthoses for arm movements. We had tetraplegics turn a crank using their paralyzed arm propelled by a planar robot manipulandum. The robot was under impedance control, and chin motion served as command source. Stiffness varied between 50, 100, or 200 N/m and damping varied between 5 or 15 N/m/s. Results indicated that a low stiffness and high viscosity provided better directional control of the tangential force exerted on the crank.

关键词

OrthoticsCrankImpedance controlStiffnessElectrical impedanceIntellectualizationMechanical impedanceRobotMechatronicsExoskeleton