Permanent magnet array–driven navigation of wireless millirobots inside soft tissues

Donghoon Son, Musab Cagri Ugurlu, Metin Sitti

发表年份
2021
引用次数
74
访问权限
开放获取

摘要

Creating wireless milliscale robots that navigate inside soft tissues of the human body for medical applications has been a challenge because of the limited onboard propulsion and powering capacity at small scale. Here, we propose around 100 permanent magnet array–based remotely propelled millirobot system that enables a cylindrical magnetic millirobot to navigate in soft tissues via continuous penetration. By creating a strong magnetic force trap with magnetic gradients on the order of 7 T/m inside a soft tissue, the robot is attracted to the center of the array even without active control. By combining the array with a motion stage and a fluoroscopic x-ray imaging system, the magnetic robot followed complex paths in an ex vivo porcine brain with extreme curvatures in sub-millimeter precision. This system enables future wireless medical millirobots that can deliver drugs; perform biopsy, hyperthermia, and cauterization; and stimulate neurons with small incisions in body tissues.

关键词

MagnetWirelessEx vivoTrap (plumbing)Electropermanent magnetPhysicsComputer scienceMaterials scienceIn vivoElectrical engineering