Home /Research /Improved Positioning Accuracy of the PA10-6CE Robot with Geometric and Flexibility Calibration
OTHER

Improved Positioning Accuracy of the PA10-6CE Robot with Geometric and Flexibility Calibration

C. Lightcap, Sam Hamner, Tony L. Schmitz, Scott A. Banks

Year
2008
Citations
111

Abstract

Accurate determination of robot geometric and flexibility parameters permits significant reduction of systematic errors and improved end-effector positioning accuracy. We apply a 30-parameter flexible geometric model to the Mitsubishi PA10-6CE robot and reduce mean/peak positional errors from 1.80/2.45 mm to 0.33/0.71 mm while loaded at 44 N.

Keywords

RobotFlexibility (engineering)CalibrationReduction (mathematics)Robot end effectorComputer scienceComputer visionRobot calibrationArtificial intelligenceRobot kinematics