首页 /研究 /Improved Positioning Accuracy of the PA10-6CE Robot with Geometric and Flexibility Calibration
OTHER

Improved Positioning Accuracy of the PA10-6CE Robot with Geometric and Flexibility Calibration

C. Lightcap, Sam Hamner, Tony L. Schmitz, Scott A. Banks

发表年份
2008
引用次数
111

摘要

Accurate determination of robot geometric and flexibility parameters permits significant reduction of systematic errors and improved end-effector positioning accuracy. We apply a 30-parameter flexible geometric model to the Mitsubishi PA10-6CE robot and reduce mean/peak positional errors from 1.80/2.45 mm to 0.33/0.71 mm while loaded at 44 N.

关键词

RobotFlexibility (engineering)CalibrationReduction (mathematics)Robot end effectorComputer scienceComputer visionRobot calibrationArtificial intelligenceRobot kinematics

相关论文