Industrial arm / Cobot

ME800 MV Industrial Drive

by Step Ia

ME800 MV Industrial Drive

Specifications

Thd percent
<5%
Altitude max m
1000
Analog inputs
4
Speed range hz
0.5 ~ 120 Hz
Analog outputs
4
Cooling method
Forced air cooling
Digital inputs
16
Vibration max g
0.9
Digital outputs
8
Overload percent
120
Protection class
IP30
Input line voltage
3/6/10kV (-10% ~ +10%)
Input power factor
0.95
Overload duration s
60
Power control phase
Three-phase four-wire
Humidity max percent
95
Power range3k v250k (w)
250kW-2500kW
Power range6k v280k (w)
280kW-8000kW
Power range10k v280k (w)
280kW-12500kW
Power range11k v280k (w)
280kW-12500kW
Power control voltage (v)
380
Power range3_3k v250k (w)
250kW-2500kW
Power range6_6k v280k (w)
280kW-8000kW
Rated input frequency hz
50
Output line voltage max kv
0 ~ 3.0/6.0/10.0 kV
Storage temperature max c
70
Storage temperature min c
-20
Input frequency tolerance
-2% ~ +2%
Power control capacity kva
5-50kVA
Operating temperature max c
40
Operating temperature min c
0
Output frequency drift percent
0.5
Output frequency resolution hz
0.01
Acceleration deceleration time s
0 ~ 3200 s

Overview

The ME800 MV Industrial Drive from STEP is a high-voltage source type drive integrating power electronic and vector control technology. It offers power ranges from 250kW to 12500kW across voltage levels of 3kV to 11kV. Features include multi-level PWM control, low harmonic distortion (THD <5%), and support for asynchronous and synchronous motors. It has a touchscreen interface, IP30 protection, and forced air cooling. Applications span power, steel, chemical, cement, rubber, sugar, and other industries.

Key features

  • Multi-level PWM control mode, providing sine wave current output
  • Low common mode voltage and du/dt, no special requirement for the motor and cable
  • Multi-pulse rectifier effectively suppresses higher harmonics, THD <5%
  • Drives asynchronous motor and synchronous motor (permanent magnet synchronous and other excitation synchronous)
  • Main control chip integrates ARM core processor; power unit control via large FPGA programming chip
  • Main control board directly communicates with IO board for DI/DO and AI/AO functions, no PLC needed
  • User interface with touchscreen
  • Protection: overvoltage, undervoltage, overcurrent, short circuit, overheating, power unit failure
  • Communication: Standard Modbus; Optional Profibus-DP
  • Transformer insulation class H
Manufacturer page