Industrial arm / Cobot

AS180 Fan & Pump Drives

by Step Ia

AS180 Fan & Pump Drives

Specifications

Input voltage (v)
380-460
Overload class
Heavy duty 150%, 1min
Overload percent
120
Speed range ratio
1:50
Input frequency hz
45-65
Applicable motor kw
2.2-630
Overload duration s
60
Efficiency full load
0.94
Output voltage range
0 VAC ~ Input voltage
Analog input channels
2
Relay output channels
2
Analog output channels
2
Digital input channels
7
Digital input voltage (v)
24
Output frequency max hz
300
Output frequency min hz
0
Relay output2 channels
2
Built in brake unit max kw
30
Built in dc reactor min kw
30
Instant drop threshold (v)
300
Carrier frequency max k hz
8
Carrier frequency min k hz
1.1
Dc braking current percent
0.0~120.0
Voltage unbalance percent
3
Analog input voltage range (v)
-10~+10
Analog input current range ma
0-20
Analog output voltage range (v)
-10~+10
Analog input accuracy percent
0.1
Analog output current range ma
0-20
Analog output accuracy percent
0.1
Instant drop protection time (ms)
15
Open collector output channels
2
Steady speed precision percent
2
Input voltage tolerance percent
-15~+10
Starting torque at0_5 hz percent
120
Starting torque at2_5 hz percent
120
High performance speed range ratio
1:200
Relay contact capacity inductive (a)
1.5
Relay2 contact capacity inductive (a)
0.4
Relay2 contact capacity resistive (a)
4.5
Frequency setting resolution digital hz
0.01
Output frequency accuracy analog percent
0.1
Output frequency accuracy digital percent
0.01
Relay contact capacity inductive voltage (v)
250
Relay2 contact capacity inductive voltage (v)
250
Relay2 contact capacity resistive voltage (v)
250
Relay2 contact capacity inductive voltage dc (v)
30
Relay2 contact capacity resistive voltage dc (v)
30
Frequency setting resolution analog hz per120 hz
0.06
High performance steady speed precision percent
0.5

Overview

The AS180 Fan & Pump Drives is a frequency drive designed for fan and pump loads, developed in Germany and manufactured in China. It features excellent V/F control performance, constant-pressure water supply, and multi-pump control. Suitable for light-load applications such as HVAC, exhaust fans, and water pumps. Overload capacity 120% for 60 seconds. Input voltage 380-460V three-phase. Applicable motor power 2.2-630 kW.

Key features

  • Dedicated fan pump drive
  • Constant-pressure water supply function
  • Several pumps controlled by one frequency drive
  • Excellent V/F control performance
  • Designed in Germany, made in China
  • Overload 120% for 60 seconds
  • Built-in brake unit for 30kW and below
  • Built-in DC reactor for 30kW and above
  • Process PID for closed-loop control
  • Common DC bus supported for full power range
Manufacturer page

More from Step Ia

Back to Step Ia