首页 /研究 /Powered Upper Limb Orthosis Actuation System Based on Pneumatic Artificial Muscles
OTHER

Powered Upper Limb Orthosis Actuation System Based on Pneumatic Artificial Muscles

Dimitar Chakarov, Ivanka Veneva, Mihail Tsveov, Pavel Venev

发表年份
2018
引用次数
2

摘要

Abstract The actuation system of a powered upper limb orthosis is studied in the work. To create natural safety in the mutual “man-robot” interaction, an actuation system based on pneumatic artificial muscles (PAM) is selected. Experimentally obtained force/contraction diagrams for bundles, consisting of different number of muscles are shown in the paper. The pooling force and the stiffness of the pneumatic actuators is assessed as a function of the number of muscles in the bundle and the supply pressure. Joint motion and torque is achieved by antagonistic actions through pulleys, driven by bundles of pneumatic muscles. Joint stiffness and joint torques are determined on condition of a power balance, as a function of the joint position, pressure, number of muscles and muscles

关键词

Pneumatic artificial musclesTorquePneumatic actuatorPulleyExoskeletonActuatorControl theory (sociology)Artificial muscleStiffnessWork (physics)