Randomized, crossover clinical trial on the safety, feasibility, and usability of the ABLE exoskeleton: A comparative study with knee-ankle-foot orthoses
Antonio Rodríguez Fernández, Joan Lobo-Prat, Mariona Tolrà-Campanyà, Florentina Pérez-Cañabate, Josep M. Font-Llagunes, Lluis Guirao-Cano
- 发表年份
- 2025
- 引用次数
- 2
摘要
Wearable exoskeletons are emerging as a new tool for gait training. However, comparisons between exoskeletons and conventional orthoses in terms of safety and feasibility are scarce. This study assessed the safety, feasibility, usability, and learning process of using the ABLE Exoskeleton in people with spinal cord injury (SCI) while comparing it with knee-ankle-foot orthoses (KAFOs). In this randomized, crossover clinical trial, 10 patients with chronic complete SCI (T4-T12) conducted a 10-session training and assessment protocol with each device: KAFOs and the ABLE Exoskeleton. Outcomes on safety (adverse events), and feasibility and usability (level of assistance, donning/doffing, therapy activities) were recorded for both devices. Evaluation sessions included standard clinical tests (Timed Up and Go, 10-Meter Walk Test, and 6-Minute Walk Test) to assess gait performance. The therapy metrics (number of steps, distance, gait speed, and standing and walking time) were recorded at each session for the robotic device. Participants quickly learned how to use the ABLE Exoskeleton, showing improvements in all therapy metrics (p<0.05) and the 6-Minute Walk Test (p<0.05). Participants reported less adverse events with the robotic device than KAFOs (17 and 31, respectively). Total donning and doffing time was 43 s faster with the robotic device using comparable levels of assistance. The time to complete the therapy activities was very similar between devices. Overall, participants needed 1 to 4 training sessions to perform essential therapy activities (sit/stand transitions, walking 10 meters, turning around) with both devices using minimum assistance or less. The results of this study show that it is feasible and safe for people with motor complete paraplegia due to SCI (T4-T12) to use the ABLE Exoskeleton for gait training in a rehabilitation hospital setting. The ABLE Exoskeleton proved to be as practical and easy to use as conventional orthoses, with fewer AEs reported when using the exoskeleton versus the KAFOs.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Trust Region Policy Optimization
John Schulman, Sergey Levine, Philipp Moritz 等 5 位作者
2015
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Legged Robots That Balance
Marc H. Raibert, Ernest R. Tello
1986