OTHER
Research on Robot's Positioning Accuracy Calibration
Yi Wang
- 发表年份
- 2007
- 引用次数
- 3
摘要
In order to improve the precision of robot position and pose,depending on robot link parameters accuracy,it is needed to calibrate the robot.Establishing a robot kinematics model,and based on MDH model and differential coefficient kinematics identifying the influence of the link parameters error on the precision of robot,the positioning accuracy of robot by least square techniques is corrected.The experiment shows this method is practicable to calibrate the robot link parameter error and can improve the over-all properties.
关键词
Robot calibrationRobotKinematicsCalibrationComputer sciencePosition (finance)Artificial intelligenceRobot kinematicsDifferential (mechanical device)Computer vision