O-124 Contact-free oocyte denudation in a chip-scale ultrasonic microfluidic device
Amir Mokhtare, Pengfei Xie, Benyamin Davaji, Alireza Abbaspourrad, Zev Rosenwaks, G.D. Palermo
- 发表年份
- 2021
- 引用次数
- 4
摘要
Abstract Study question To design and test an automated microfluidic device to revolutionize the cumulus-oocyte-complex (COC) denudation procedure for intracytoplasmic sperm injection (ICSI) using murine oocytes. Summary answer Oocyte exposure to temperature variation, mechanical stress, and prolonged chemical treatment during denudation was mitigated using our microfluidic device based on surface acoustic waves (SAWs). What is known already COC denudation is a prerequisite for many ART procedures such as ICSI. However, this procedure is based on manual pipetting (MP), which lacks standardization and requires experienced embryologists to perform. Inadequate MP may damage oocytes through prolonged enzymatic treatment or high fluidic stresses and may jeopardize gamete competence. The use of microfluidic devices based on porous membranes or microchannels has been adopted by many laboratories for sperm selection. Of these, microchannel devices may also be adapted for denudation with minimal mechanical stress in a controlled microenvironment. However, oocyte manipulation and extraction have proven difficult to achieve. Study design, size, duration We developed a novel ultrasonic microfluidic device based on a microwell design manufactured with Polydimethylsiloxane (PDMS). The SAWs were generated by 4 interdigitated transducers (IDTs) arranged in an orthogonally symmetric pattern. A non-toxic dosage of ultrasonic waves, similar to those used in gynecology and obstetrics, was applied. COCs were denuded by induced acoustic streaming and acoustic radiation force. Denudation rate, embryo development, and pregnancy outcomes were assessed and compared to control oocytes denuded by MP. Participants/materials, setting, methods For each run, up to 10 individual COCs from super-ovulated B6D2F1 mice were loaded into the microwell alongside diluted hyaluronidase (20 IU/ml) and denuded by 80 or 200 MHz SAWs. Denuded oocytes were fertilized by piezo-actuated ICSI using spermatozoa from the same strain. Pre-implantation embryo development was assessed in a time-lapse incubator for up to 96 h. High-quality blastocysts were transferred to 2.5-dpc pseudo-pregnant CD-1 surrogates. Pregnancy and offspring health were observed. Main results and the role of chance Using alternating frequency sweep in a pulse-repetition mode, we swirled the fluid inside the microwell consistently and tumbled COCs inside the microwell to expose them to acoustic steaming-induced drag forces and acoustic radiation force. Using a high-speed camera and particle-tracking technique, we observed that the drag force generated by the SAWs fulfilled the denudation mechanism. Additionally, due to the small attenuation coefficient in water, thermal absorption heating remains minuscule, preventing any thermal-induced damage. Our device significantly reduced the time and labor of the denudation process. It also yielded proper denudation quality without oocyte loss. To ensure that SAWs do not damage oocytes, 40 oocytes denuded by 80 MHz SAWs, 25 oocytes denuded by 200 MHz SAWs, and 30 oocytes denuded by MP were inseminated by piezo-actuated ICSI. The 80-MHz, 200-MHz, and MP groups yielded comparable post-ICSI survival (82.5% vs. 84.0% vs. 83.3%, respectively), fertilization (80.0% vs. 80.0% vs. 83.3%,respectively), and blastulation rates (72.5% vs. 82.0% vs. 66.7%, respectively). Embryo morphokinetics were also not impacted. After transferring all blastocysts into recipient mice, 8 live births were achieved from the 80-MHz group, while 5 were achieved from the 200-MHz group. Limitations, reasons for caution Although PDMS is a popular material due to its high optical transparency and biocompatibility, adverse effects due to gas permeability and small-molecule adsorption cannot be excluded. Large-scale mouse embryo assays should be performed to assess the teratogenicity of PDMS. Operation parameters must be optimized for human COCs in clinical application. Wider implications of the finding
关键词
相关论文
Quantitative Monitoring of Gene Expression Patterns with a Complementary DNA Microarray
Mark Schena, Dari Shalon, Ronald W. Davis 等 4 位作者
1995
Real-Time Obstacle Avoidance for Manipulators and Mobile Robots
Oussama Khatib
1986
A Mathematical Introduction to Robotic Manipulation
Richard M. Murray, Zexiang Li, Shankar Sastry
2017
Robot dynamics and control
Mark W. Spong
1989