首页 /研究 /Detection of increased intracranial pressure in trans‐oral robotic thyroidectomy using optic nerve sheath diameter measurement
OTHER

Detection of increased intracranial pressure in trans‐oral robotic thyroidectomy using optic nerve sheath diameter measurement

Hyunyoung Lim, Eugene Kim, Soo Yeon Kim, Ji‐Yoon Kim, Yundo Jung, Tagkeun Lee, Nayeon Kim, Kyung Tae

发表年份
2022
引用次数
5

摘要

Abstract Background During transoral robot‐assisted thyroidectomy, there is a risk of increasing intracranial pressure because the site of CO 2 insufflation is narrow and close to the brain. Methods We analyzed the pre‐ to post‐CO 2 neck insufflation change in the optic nerve sheath diameter during transoral robot‐assisted thyroidectomy. Changes in vital‐signs, airway pressure, and arterial carbon dioxide pressure were analyzed along with postoperative complications. Results Among the 30 participants, the post‐CO 2 inflation mean optic nerve sheath diameter (5.64 ± 0.54 mm) was higher than the pre‐induction diameter (4.81 ± 0.37 mm) with a mean difference of 0.83 (95% CI, 0.69–0.97; p < 0.001), but returned to baseline after CO 2 deflation in most cases. One participant had sustained increased optic nerve sheath diameter (6.35 mm) associated with severe new‐onset postoperative headache. Conclusion Transient elevation in the intracranial pressure during low‐pressure CO 2 neck insufflation in the transoral robot‐assisted thyroidectomy did not appear to adversely affect patients.

关键词

MedicineInsufflationAnesthesiaThyroidectomyAirwayOptic nerveSuperior laryngeal nerveIntracranial pressureSurgeryThyroid

相关论文