首页 /研究 /Preferred Oil and Ceramics Options for EHA Drive Systems and Computed Torque Control of an EHA-Driven Robot Manipulator
HRI

Preferred Oil and Ceramics Options for EHA Drive Systems and Computed Torque Control of an EHA-Driven Robot Manipulator

Mitsuo Komagata, Yutaro Imashiro, Ko Yamamoto, Yoshihiko Nakamura

发表年份
2021
引用次数
6

摘要

6-DOF robot manipulator Hydracer was developed to gain high output torque and high backdrivability by adopting electro-hydrostatic actuators, however control of overall system of Hydracer is not yet conducted. To achieve flexible force control of Hydracer, we worked on the system improvements: enhancement of reliability of ceramics components, reduction of internal leakage by considering the property of hydraulic oil, and the identification of inertial parameters to improve its controllability. By using identified parameters, flexible force control of Hydracer by zero-torque control with gravity compensation was realized which reveals the potential of safe human-robot interaction.

关键词

ControllabilityTorqueElectro-hydraulic actuatorControl theory (sociology)ActuatorRobotEngineeringControl engineeringControl systemCompensation (psychology)

相关论文

查看 HRI 分类全部论文