Robotic Diagnostic Cerebral Angiography: A Multicenter Experience of 113 Patients
Charles Beaman, Ayushi Gautam, Catherine Peterson, Naoki Kaneko, Hamidreza Saber, Kasra Khatibi, José Morales, David Kimball, Jacob R. Lipovac, Kazim Narsinh, Amanda Baker, M. Travis Caton, Eric R. Smith, May Nour, Viktor Szeder, Reza Jahan, Geoffrey P. Colby, Branden Cord, Daniel L. Cooke, Satoshi Tateshima
- 发表年份
- 2023
- 引用次数
- 10
摘要
BACKGROUND: Neurointerventional robotic systems have potential to reduce occupational radiation, improve procedural precision, and allow for future remote teleoperation. A limited number of single institution case reports and series have been published outlining the safety and feasibility of robot-assisted diagnostic cerebral angiography. METHODS: This is a multicenter, retrospective case series of patients undergoing diagnostic cerebral angiography at three separate institutions - University of California, Davis (UCD); University of California, Los Angeles (UCLA); and University of California, San Francisco (UCSF). The equipment used was the CorPath GRX Robotic System (Corindus, Waltham, MA). RESULTS: A total of 113 cases were analyzed who underwent robot-assisted diagnostic cerebral angiography from September 28, 2020 to October 27, 2022. There were no significant complications related to use of the robotic system including stroke, arterial dissection, bleeding, or pseudoaneurysm formation at the access site. Using the robotic system, 88 of 113 (77.9%) cases were completed successfully without unplanned manual conversion. The principal causes for unplanned manual conversion included challenging anatomy, technical difficulty with the bedside robotic cassette, and hubbing out of the robotic system due to limited working length. For robotic operation, average fluoroscopy time was 13.2 min (interquartile range (IQR), 9.3 to 16.8 min) and average cumulative air kerma was 975.8 mGY (IQR, 350.8 to 1073.5 mGy). CONCLUSIONS: Robotic cerebral angiography with the CorPath GRX Robotic System is safe and easily learned by novice users without much prior manual experience. However, there are technical limitations such as a short working length and an inability to support 0.035" wires which may limit its widespread adoption in clinical practice.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
The Uncanny Valley [From the Field]
Masahiro Mori, Karl F. MacDorman, Norri Kageki
2012
Measurement Instruments for the Anthropomorphism, Animacy, Likeability, Perceived Intelligence, and Perceived Safety of Robots
Christoph Bartneck, Dana Kulić, Elizabeth A. Croft 等 4 位作者
2008
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012