Home /Research /An Integrated Dynamic Closed Loop Simulation Platform for Elbow Flexion Augmentation Using an Upper Limb Exosuit Model
OTHER

An Integrated Dynamic Closed Loop Simulation Platform for Elbow Flexion Augmentation Using an Upper Limb Exosuit Model

Ratna Sambhav, Shreeshan Jena, Ankit Chatterjee, Shubhendu Bhasin, Sushma Santapuri, Lalan Kumar, Suriya Prakash Muthukrishnan, Sitikantha Roy

Year
2022
Citations
10
Access
Open access

Abstract

Wearable robotic devices are designed to assist, enhance or restore human muscle performance. Understanding how a wearable robotic device changes human biomechanics through complex interaction is important to guide its proper design, parametric optimization and functional success. The present work develops a human-machine-interaction simulation platform for closed loop dynamic analysis with feedback control and to study the effect of soft-robotic wearables on human physiology. The proposed simulation platform incorporates Computed Muscle Control (CMC) algorithm and is implemented using the MATLAB -OpenSim interface. The framework is generic and will allow incorporation of any advanced control strategy for the wearable devices. As a demonstration, a Gravity Compensation (GC) controller has been implemented on the wearable device and the resulting decrease in the joint moments, muscle activations and metabolic costs during a simple repetitive load lifting task with two different speeds is investigated.

Keywords

Computer scienceWearable computerExoskeletonController (irrigation)Powered exoskeletonSimulationRehabilitation roboticsRobotArtificial intelligenceEmbedded system

Related papers

Browse all OTHER papers