Advanced Robotic Angiography Systems for Image Guidance During Conventional Transarterial Chemoembolization

Thomas J. Vogl, Leona S. Alizadeh, R Maeder, N Naguib, Eva Herrmann, Matthew W. Bickford, Iris Burck, Moritz H. Albrecht

发表年份
2018
引用次数
11

摘要

OBJECTIVES: The aim of this study was to compare 2 advanced robotic angiography systems for real-time image guidance in terms of radiation dose and image quality (IQ) during conventional transarterial chemoembolization (C-TACE) of hepatic malignant tumors. MATERIALS AND METHODS: One hundred six patients (57 women/49 men; mean age, 60 ± 11 years) who had undergone C-TACE using 2 generations of robotic angiography platforms for image guidance were included in this retrospective study. Patients were divided into 2 groups (n = 53, respectively): group 1 (first generation) and group 2 (second generation). Radiation dose for fluoroscopy and digital subtraction angiography (DSA) was compared between first-generation and second-generation angiography equipment, respectively. Among several features of the second-generation compared with the first-generation system, improvements included a refined crystalline detector system for enhanced noise reduction and advanced CARE filter software for lowering radiation dose. Radiation dose was measured using an ionization chamber. Image quality was assessed by 3 radiologists using 5-point Likert scales. RESULTS: Both groups were comparable in terms of number and location of lesions, as well as body weight, body mass index, and anatomical variants of feeding hepatic arteries (all P > 0.05). Dose-area product (DAP) for fluoroscopy was significantly lower in group 2 (1.4 ± 1.1 Gy·cm) compared with group 1 (2.8 ± 3.4 Gy·cm; P = 0.001). For DSA, DAP was significantly lower (P = 0.003) in group 2 (2.2 ± 1.2 Gy·cm) versus group 1 (4.7 ± 2.3 Gy·cm). Scores for DSA IQ indicated significant improvements for group 2 by 30% compared with group 1 (P = 0.004). Regarding fluoroscopy, scores for IQ were 76% higher in group 2 compared with group 1 (P = 0.001). Good to excellent interrater agreement with Fleiss kappa coefficients of κ = 0.75 for group 1 and κ = 0.74 for group 2 were achieved. CONCLUSIONS: Most recent generation robotic angiography equipment allows for considerable radiation dose reductions while improving IQ in fluoroscopy and DSA image guidance during C-TACE treatment.

关键词

MedicineDigital subtraction angiographyFluoroscopyAngiographyImage qualityRadiologyNuclear medicineRadiation dose

相关论文

查看 OTHER 分类全部论文