Clinical Results of Mean GTV Dose Optimized Robotic-Guided Stereotactic Body Radiation Therapy for Lung Tumors
René Baumann, M Chan, Florian Pyschny, Susanne Stera, Bettina Malzkuhn, Stefan Wurster, Stefan Huttenlocher, Marcella Szücs, Detlef Imhoff, C. Keller, Panagiotis Balermpas, Dirk Rades, Claus Rödel, Jürgen Dunst, Guido Hildebrandt, Oliver Blanck
- 发表年份
- 2018
- 引用次数
- 30
- 访问权限
- 开放获取
摘要
Introduction: We retrospectively evaluated the efficacy and toxicity of GTV mean dose optimized SBRT for primary and secondary lung tumors with and without robotic real-time motion-compensation. Material and Methods: Between 2011 and 2017, 208 patients were treated with SBRT for 111 primary lung tumors and 163 lung metastases with a median GTV of 8.2cc (0.3–174.0cc). Monte Carlo dose optimization was performed prioritizing GTV mean dose at the potential cost of PTV coverage reduction while adhering to safe normal tissue constraints. The median GTV mean BED10 was 162.0Gy10 (34.2–253.6Gy10) and the prescribed PTV BED10 ranged 23.6–151.2Gy10 (median, 100.8Gy10). Motion compensation was realized through direct tracking (44.9%), fiducial tracking (4.4%) and Internal Target Volume (ITV) concepts with small (≤5mm, 33.2%) or large (>5mm, 17.5%) motion. The local control (LC), progression-free survival (PFS), overall survival (OS), and toxicity were analyzed. Results: Median follow-up was 14.5 months (1–72 months). The 2-year actuarial LC, PFS, and OS rates were 93.1%, 43.2%, and 62.4%, and the median PFS and OS were 18.0 and 39.8 months, respectively. In univariate analysis prior local irradiation (HR 0.18, CI 0.05–0.63, p=0.01), GTV/PTV (HR 1.01–1.02, CI 1.01–1.04, p<0.02) and PTV prescription, mean GTV and maximum plan BED10 (HR 0.97–0.99, CI 0.96–0.99, p<0.01) were predictive for LC while the tracking method was not (p=0.97). For PFS and OS, multivariate analysis showed Karnofsky Index (p<0.01) and tumor stage (p≤0.02) to be significant factors for outcome prediction. Late radiation pneumonitis or chronic rip fractures grade 1-2 were observed in 5.3% of the patients. Grade ≥ 3 side effects did not occur. Conclusions: Robotic SBRT is a safe and effective treatment for lung tumors. Reducing the PTV prescription and keeping high GTV mean doses allowed the reduction of toxicity while maintaining high local tumor control. The use of real-time motion-compensation is strongly advised, however well performed ITV motion compensation may be used alternatively when direct tracking is not feasible.
关键词
相关论文
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Fractional Differential Equations
Igor Podlubný
2025
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
Genetic Programming: On the Programming of Computers by Means of Natural Selection
John R. Koza
1992