Precision versus Tradition: A Meta-Analysis Comparing Robotic and Conventional Minimally Invasive Pedicle Screw Instrumentation in Thoracolumbar Fractures
Paweł Łajczak, Oguz Kagan Sahin, Eshita Sharma, Ayesha Ayesha, Anna Łajczak
- Year
- 2025
- Citations
- 1
Abstract
BACKGROUND: Robotic-assisted minimally invasive surgery (RA-MIS) is becoming increasingly applied to spinal surgery, offering an alternative to conventional minimally invasive spinal surgery (C-MIS). Recently, RA-MIS has been proposed for pedicle screw instrumentation in thoracolumbar fractures. This review aims to evaluate RA-MIS and C-MIS among the thoracolumbar fracture population. METHODS: This study followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses and Cochrane guidelines. 5 medical databases were searched. Finally, 10 studies were included in the meta-analysis, with a total of 562 patients. Outcomes on operation time, blood loss, pedicle screw accuracy, complications, and cost-effectiveness were evaluated. RESULTS: RA-MIS showed superiority in terms of accurate (Gertzbein and Robbins [GR] A) screw placement (odds ratio [OR]: 3.58, 95% confidence interval [CI]: 2.30-5.58, P < 0.001) and satisfactory (GR A+B) screw placement (OR: 3.86, 95% CI: 2.14-6.96, P < 0.001) compared to C-MIS. RA-MIS led to a significantly lower incidence of severely misplaced (GR D+E) screws (OR: 0.26, 95% CI: 0.13-0.51, P < 0.001) and lower blood loss (mean difference [MD]: -12.03, 95% CI: -20.85 to -3.21, P < 0.01). However, we found no statistically significant differences in operation time (MD: -4.92, 95% CI: -12.06 to 2.22, P = 0.18) or complications (screw loosening, nerve injury, or infection). Costs of RA-MIS were significantly higher (MD: ¥8657.61, 95% CI: 6651.39 to 10,663.83, P < 0.01). CONCLUSIONS: Robotic-assisted minimally invasive spinal surgery is superior in terms of higher pedicle screw accuracy and reduced perioperative blood loss, at the cost of significantly higher costs of surgery. Furthermore, we observed no clear advantages regarding complication rate and total operation time. Future trials should provide a less biased methodology to confirm the findings.
Keywords
Related papers
Self-Organizing Maps
Teuvo Kohonen
1995
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz +8 more
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012