Home /Research /Needle placement accuracy in CT-guided robotic post mortem biopsy
OTHER

Needle placement accuracy in CT-guided robotic post mortem biopsy

Martin Gromniak, Maximilian Neidhardt, Axel Heinemann, Klaus Püschel, Alexander Schlaefer

Year
2020
Citations
4
Access
Open access

Abstract

Abstract Forensic autopsies include a thorough examination of the corpse to detect the source or alleged manner of death as well as to estimate the time since death. However, a full autopsy may be not feasible due to limited time, cost or ethical objections by relatives. Hence, we propose an automated minimal invasive needle biopsy system with a robotic arm, which does not require any online calibrations during a procedure. The proposed system can be easily integrated into the workflow of a forensic biopsy since the robot can be flexibly positioned relative to the corpse. With our proposed system, we performed needle insertions into wax phantoms and livers of two corpses and achieved an accuracy of 4.34 ± 1.27 mm and 10.81 ± 4.44 mm respectively.

Keywords

WorkflowBiopsyNeedle biopsyTime of deathComputer scienceAutopsyArtificial intelligenceComputer visionRadiologyMedicine

Related papers

Browse all OTHER papers