Home /Research /Two-Port Robotic Cardiac Surgery (TROCS) for Atrial Septal Defect (ASD) Using Cross-Arm Technique – TROCS ASD Repair –
SURGICAL

Two-Port Robotic Cardiac Surgery (TROCS) for Atrial Septal Defect (ASD) Using Cross-Arm Technique – TROCS ASD Repair –

Norihiko Ishikawa, Go Watanabe, Tatsuya Tarui, Ryuta Kiuchi, Hiroshi Ohtake, Shigeyuki Tomita, Kenji Kawachi

Year
2015
Citations
8
Access
Open access

Abstract

BACKGROUND: We successfully performed totally endoscopic atrial septal defect (ASD) repair via 2 ports, and we named this procedure two-port robotic cardiac surgery (TROCS).Methods and Results:A 51-year-old woman with secundum ASD underwent robot-assisted ASD repair under ventricle fibrillation without aortic cross-clamping. Two ports were placed in the right side of the chest, and 1 port was for the robotic endoscope. Two robotic instruments were inserted through another port and crossed while preventing them from colliding. CONCLUSIONS: TROCS ASD repair using a cross-arm technique was achieved safely with good clinical results and excellent cosmetic results.

Keywords

Cardiac surgeryPort (circuit theory)MedicineSurgeryVentricleRobotic surgeryAtrial fibrillationSeptum secundumCardiologyEngineering