CyberKnife robotic spinal radiosurgery in prone position: dosimetric advantage due to posterior radiation access?
Christoph Fürweger, Christian Drexler, Alexander Muacevic, Berndt Wowra, Erik C. de Klerck, Mischa S. Hoogeman
- Year
- 2014
- Citations
- 14
- Access
- Open access
Abstract
CyberKnife spinal radiosurgery suffers from a lack of posterior beams due to workspace limitations. This is remedied by a newly available tracking modality for fiducial-free, respiration-compensated spine tracking in prone patient position. We analyzed the potential dosimetric benefit in a planning study. Fourteen exemplary cases were compared in three scenarios: supine (PTV=CTV), prone (PTV=CTV), and prone position with an additional margin (PTV=CTV+2 mm), to incorporate reduced accuracy of respiration-compensated tracking. Target and spinal cord constraints were chosen according to RTOG 0631 protocol for spinal metastases. Plan quality was scored based on four predefined parameters: dose to cord (D0.1cc and D1cc), high dose (V10Gy), and low dose (V4Gy) volume of healthy tissue. Prescription dose was 16 Gy to the highest isodose line encompassing 90% of the target. Results were related to target size and position. All plans fulfilled RTOG 0631 constraints for coverage and dose to cord. When no additional margin was applied, a majority of eight cases benefitted from prone position, mainly due to a reduction of V4Gy by 23% ± 26%. In the 2 mm prone scenario, the benefit was nullified by an average increase of V10Gy by 43% ± 24%, and an increase of D1cc to cord (four cases). Spinal cord D0.1cc was unchanged (< ± 1 Gy) in all but two cases for both prone scenarios. Conformity (nCI) and number of beams were equivalent in all scenarios, but supine plans used a significantly higher number of monitor units (+16%) than prone. Posterior beam access can reduce dose to healthy tissue in CyberKnife spinal radiosurgery when no additional margin is applied. When a target margin of 2 mm is added, this potential gain is lost. Relative anterior-posterior position and size of the target are selection criteria for prone treatment.
Keywords
Related papers
A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses
R. Tsai
1987
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Hybrid Position/Force Control of Manipulators
Marc H. Raibert, John Craig
1981
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz +8 more
2012