Home /Research /Design and development of a safe robot manipulator using a new actuation concept
MANIPULATION

Design and development of a safe robot manipulator using a new actuation concept

Peyman Yadmellat, Alexander S. Shafer, Mehrdad R. Kermani

Year
2013
Citations
17

Abstract

This paper presents the design and development of a novel two Degrees-Of-Freedom (DOF) safe robot manipulator. Magneto-Rheological (MR) clutches are incorporated in the design to enable antagonistic actuation at the joints. A single unidirectional motor supports bidirectional actuation of all joints. Unlike most current safe robots, high quality actuation is preserved, while the manipulator weight and effective inertia are reduced. This is achieved by relocating the driving motor to the base of the robot. Moreover, MR clutches have been shown to pose superior torque to mass, and torque to inertia characteristics over conventional servo motors, further contributing to the reduction of manipulator mass and inertia. The manipulator exhibits both high performance and intrinsic safety as a result of mechanically passive dynamics. A set of experiments is performed to validate the manipulator performance.

Keywords

InertiaTorqueMobile manipulatorClutchRobotManipulator (device)Control theory (sociology)ServomotorParallel manipulatorComputer science

Related papers