首页 /研究 /Anastomotic leakage following robot-assisted minimally invasive esophagectomy (RAMIE): which anastomosis should be preferred?
OTHER

Anastomotic leakage following robot-assisted minimally invasive esophagectomy (RAMIE): which anastomosis should be preferred?

Cezanne D. Kooij, Michele Manigrasso, Lucas Goense, Marc J. van Det, Ewout A. Kouwenhoven, Suzanne S. Gisbertz, Beat P. Müller‐Stich, Philipp Lingohr, Takeo Fujita, Hans F. Fuchs, Christiane J. Bruns, Dolores T. Krauss, Jan Willem Haveman, Boudewijn van Etten, Daniel Pérez, Jan-Hendrik Egberts, Paul Turner, Guillaume Piessen, Frank Benedix, Peter Grimminger

发表年份
2025
引用次数
4
访问权限
开放获取

摘要

BACKGROUND: The optimal technique for intrathoracic esophagogastric anastomosis in esophagectomy remains undetermined. This study evaluates different anastomotic techniques in robot-assisted minimally invasive esophagectomy (RAMIE) and their impact on anastomotic leakage rates. MATERIALS AND METHODS: This observational, retrospective, comparative cohort study analyzed data obtained from the Upper GI International Robotic Association (UGIRA) Esophageal Registry. All consecutive patients with a histologically proven esophageal malignancy who underwent RAMIE with intrathoracic esophagogastrostomy were included. The anastomotic technique was performed based on the clinical judgement and expertise of each individual surgeon. For comparison, the four most common techniques were included: circular end-to-side, linear side-to-side, handsewn end-to-side, and handsewn end-to-end. The primary endpoint of this study was the occurrence of anastomotic leakage, defined by the Esophagectomy Complications Consensus Group as a full-thickness gastrointestinal defect involving the esophagus, anastomosis, staple line, or conduit, regardless of its presentation or method of identification. RESULTS: Between 2016 and September 2023, 1518 patients were included. Univariable analysis demonstrated that the linear stapled side-to-side anastomosis was associated with the lowest anastomotic leakage rate (14.0%), while the handsewn end-to-end anastomosis had the highest (32.8%) (p < 0.001). The anastomotic leakage rates for circular end-to-side and handsewn end-to-side anastomoses were 19.4% and 26.9%, respectively. Multivariable analysis confirmed that anastomotic technique was independently associated with anastomotic leakage. Specifically, handsewn anastomoses were associated with a higher risk of anastomotic leakage for both end-to-side (OR 1.675, 95% CI 1.195-2.348, p = 0.003) and end-to-end (OR 2.181, 95% CI 1.403-3.390, p < 0.001) techniques compared to circular end-to-side anastomoses. CONCLUSIONS: In RAMIE, linear side-to-side and circular end-to-side stapled anastomoses are associated with lower anastomotic leakage rates compared to handsewn techniques. While acknowledging the multifactorial complexity of anastomotic leakage, these findings favor the use of mechanical stapling in clinical practice.

关键词

RamieMedicineAnastomosisSurgeryEsophagectomyLeakage (economics)Esophageal cancerMaterials scienceInternal medicineCancer

相关论文

查看 OTHER 分类全部论文