首页 /研究 /Comparing Two Safe Distance Maintenance Algorithms for a Gaze-Controlled HRI Involving Users with SSMI
HRI

Comparing Two Safe Distance Maintenance Algorithms for a Gaze-Controlled HRI Involving Users with SSMI

Vinay Sharma, L. R. D. Murthy, Pradipta Biswas

发表年份
2022
引用次数
8

摘要

People with severe speech and motor impairment often find it difficult to manipulate physical objects due to spasticity and have familiarity with eye pointing based communication. This article presents a novel eye gaze controlled augmented reality human-robot interface that maintains a safe distance of the robot from the operator. We used a bespoke appearance-based eye gaze tracking algorithm and compared two different safe distance maintenance algorithms. We undertook simulation studies followed by a user trial involving end users. Users with severe speech and motor impairment could bring the robotic arm at any designated point within its working envelope in less than 3 minutes.

关键词

BespokeGazeComputer scienceEye trackingRobotHuman–computer interactionMotor impairmentComputer visionInterface (matter)Point (geometry)

相关论文