Evaluation of margins during radical prostatectomy: confocal microscopy vs frozen section analysis

Gennaro Musi, Francesco Alessandro Mistretta, Mariia Ivanova, Ottavio De Cobelli, Andrea Bellin, Gianluca Vago, Gabriella Pravettoni, Oriana Pala, Daniela Lepanto, Danilo Bottero, Mattia Luca Piccinelli, M. Tallini, Giulia Marvaso, Matteo Ferro, Giuseppe Petralia, Barbara Alicja Jereczek‐Fossa, Nicola Fusco, Giuseppe Renne, Stefano Luzzago

发表年份
2024
引用次数
14

摘要

OBJECTIVES: To test the performance of ex vivo fluorescence confocal microscopy (FCM; Vivascope 2500M-G4), as compared to intra-operative frozen section (IFS) analysis, to evaluate surgical margins during robot-assisted radical prostatectomy (RARP), with final pathology as the reference standard. METHODS: Overall, 54 margins in 45 patients treated with RARP were analysed with: (1) ex vivo FCM; (2) IFS analysis; and (3) final pathology. FCM margins were evaluated by two different pathologists (experienced [M.I.: 10 years] vs highly experienced [G.R.: >30 years]) as strongly negative, probably negative, doubtful, probably positive, or strongly positive. First, inter-observer agreement (Cohen's κ) between pathologists was tested. Second, we reported the sensitivity, specificity, positive predictive (PPV) and negative predictive value (NPV) of ex vivo FCM. Finally, agreement between ex vivo FCM and IFS analysis (Cohen's κ) was reported. For all analyses, four combinations of FCM results were evaluated. RESULTS: At ex vivo FCM, the inter-observer agreement between pathologists ranged from moderate (κ = 0.74) to almost perfect (κ = 0.90), according to the four categories of results. Indeed, at ex vivo FCM, the highly experienced pathologist reached the best balance between sensitivity (70.5%) specificity (91.8%), PPV (80.0%) and NPV (87.1%). Conversely, on IFS analysis, the sensitivity, specificity, PPV and NPV were, respectively, 88.2% vs 100% vs 100% vs 94.8%. The agreement between the ex vivo FCM and IFS analyses ranged from moderate (κ = 0.62) to strong (κ = 0.86), according to the four categories of results. CONCLUSION: Evaluation of prostate margins at ex vivo FCM appears to be feasible and reliable. The agreement between readers encourages its widespread use in daily practice. Nevertheless, as of today, the performance of FCM seems to be sub-par when compared to the established standard of care (IFS analysis).

关键词

Ex vivoProstatectomyMedicineIn vivoProstateUrologyNuclear medicinePathologyFrozen section procedurePredictive value

相关论文

查看 SURGICAL 分类全部论文