首页 /研究 /Estimation of Physiological Tremor from Accelerometers for Real-Time Applications
SURGICAL

Estimation of Physiological Tremor from Accelerometers for Real-Time Applications

Kalyana C. Veluvolu, Wei Tech Ang

发表年份
2011
引用次数
116
访问权限
开放获取

摘要

Accurate filtering of physiological tremor is extremely important in robotics assisted surgical instruments and procedures. This paper focuses on developing single stage robust algorithms for accurate tremor filtering with accelerometers for real-time applications. Existing methods rely on estimating the tremor under the assumption that it has a single dominant frequency. Our time-frequency analysis on physiological tremor data revealed that tremor contains multiple dominant frequencies over the entire duration rather than a single dominant frequency. In this paper, the existing methods for tremor filtering are reviewed and two improved algorithms are presented. A comparative study is conducted on all the estimation methods with tremor data from microsurgeons and novice subjects under different conditions. Our results showed that the new improved algorithms performed better than the existing algorithms for tremor estimation. A procedure to separate the intended motion/drift from the tremor component is formulated.

关键词

AccelerometerComputer scienceDuration (music)RoboticsArtificial intelligenceRobotAcoustics

相关论文

查看 SURGICAL 分类全部论文