Motion Compensation for Real Time Ultrasound Scanning in Robotically Assisted Prostate Biopsy Procedures
Matija Markulin, Luka Matijević, Luka Siktar, Janko Jurdana, Branimir Caran, Marko Švaco, Filip Šuligoj, Bojan Šekoranja
- 发表年份
- 2026
- 访问权限
- 开放获取
摘要
Prostate cancer is one of the most common types of cancer in men. Its diagnosis by biopsy requires a high level of expertise and precision from the surgeon, so the results are highly operator-dependent. The aim of this work is to develop a robotic system for assisted ultrasound (US) examination of the prostate, a prebiopsy step that could reduce the dexterity requirements and enable faster, more accurate and more available prostate biopsy. We developed and validated a laboratory setup with a collaborative robotic arm that can autonomously scan a prostate phantom and attached the phantom to a medical robotic arm that mimics the patient's movements. The scanning robot keeps the relative position of the US probe and the prostate constant, ensuring a consistent and robust approach to reconstructing the prostate. To reconstruct the prostate, each slice is segmented to generate a series of prostate contours converted into a 3D point cloud used for biopsy planning. The average scan time of the prostate was 30 s, and the average 3D reconstruction of the prostate took 3 s. We performed four motion scenarios: the phantom was scanned in a stationary state (S), with horizontal motion (H), with vertical motion (V), and with a combination of the two (C). System validation is performed by registering the prostate point cloud reconstructions acquired during different motions (H, V, C) with those obtained in the stationary state. ICP registration with a threshold of 0.8 mm yields mean 83.2\% fitness and 0.35 mm RMSE for S-H registration, 84.1\% fitness and 0.37 mm RMSE for S-V registration and 79.4\% fitness and 0.37 mm RMSE for S-C registration. Due to the elastic and soft material properties of the prostate phantom, the maximum robot tracking error was 3 mm, which can be sufficient for prostate biopsy according to medical literature. The maximum delay in motion compensation was 0.5 s.
关键词
相关论文
机器人技术在整形外科中的应用
Vijay Kumar, Sandhya Pandey
Clinical Journal of Plastic & Reconstructive Surgery · 2026
SurfSurg6D:面向无纹理手术器械的几何一致密集对应位姿估计
Daiyun Shen, Shuojue Yang, Chang Han Low 等 7 位作者
2026
EndoGSim:基于MLLM引导的高斯泼溅的物理感知4D动态内窥镜场景模拟
Changjing Liu, Yiming Huang, Long Bai 等 5 位作者
2026
腹膜后机器人辅助肾输尿管切除术:技术描述与单中心经验
Kawashima A, Ishizuya Y, Yamamoto Y 等 12 位作者
Asian journal of endoscopic surgery · 2026