Home /Research /A REMOTE CONTINUOUS AIR MONITORING SYSTEM FOR MEASURING AIRBORNE ALPHA CONTAMINATION
OTHER

A REMOTE CONTINUOUS AIR MONITORING SYSTEM FOR MEASURING AIRBORNE ALPHA CONTAMINATION

Yuki Morishita, Hiroshi Usami, Yoshihiro Furuta, Katsunori Aoki, Koji Tsurudome, Katsuya Hoshi, Tatsuo Torii

Year
2020
Citations
2

Abstract

We developed a remote continuous air monitoring (RCAM) system. The RCAM system consisted of a personal air monitor and a robot. The personal air monitor (poCAMon, SARAD, Germany) had a 400-mm2 ion-injected silicon detector and a membrane air filter with 25 mmφ. The personal air monitor provides the alpha energy spectra for any measurement time interval. Demonstration measurements were taken underground at the Mizunami Underground Research Laboratory and at a poorly ventilated concrete building. The RCAM system was remotely operated and successfully measured the 222Rn progeny even though the relative humidity was almost 100%. In the measured alpha spectra, the peaks of 218Po (6.0-MeV alpha) and 214Po (7.7-MeV alpha) were clearly identified. Our developed monitor is promising for alpha dust monitoring in a high gamma-ray environment or contaminated areas where a worker cannot safely physically enter.

Keywords

Environmental scienceContaminationAir filterAir monitoringAlpha (finance)Relative humidityHumidityRemote sensingMeteorologyEnvironmental engineering

Related papers

Browse all OTHER papers