Longitudinal outcomes following international multicentre experience with robotic aortic valve replacement
Lawrence M. Wei, Daniel Pereda, Danny Ramzy, Feras Khaliel, Ghulam Murtaza, J Hunter Mehaffey, Nai‐Hsin Chi, Robinson Poffo, Štěpán Černý, Jan Vojáček, Tristan D. Yan, Serguei Melnitchouk, Alberto Weber, Robert L. Smith, Goya V. Raikar, Ali Darehzereshki, Arnar Geirsson, Arman Arghami, José Navia, Johannes Bonatti
- 发表年份
- 2025
- 引用次数
- 9
摘要
OBJECTIVES: In an effort to maintain the technical aspects of traditional prosthetic surgical aortic valve replacement (AVR) while reducing invasiveness and facilitate options for concomitant operations, transaxillary lateral mini-thoracotomy endoscopic robotic-assisted aortic valve replacement (RAVR) has been introduced. The present data highlight the contemporary international collaborative experience. METHODS: All consecutive patients undergoing standardized RAVR across 10 international sites (1/2020-7/2024) were evaluated using a central database with 1 year follow-up. RESULTS: A total of 300 patients were analysed with a median predicted risk of 1.6% with aortic stenosis in 85.7%, nearly half with bicuspid valves. Biological prostheses were implanted in 220 (73.3%) with a median valve size 23 mm, 10% receiving aortic root enlargement, with 17% of all patients undergoing concomitant procedures. Median cross-clamp 120 min with no conversions to sternotomy. Median length of stay was 5 days, 4.3% with prolonged ventilation, 1.7% renal failure, 1.0% stroke and 8.3% required re-thoracotomy for evacuation of haemothorax. There were two 30-day operative mortalities (0.7%). The new permanent pacemaker rate for the full cohort was 2.6%. Of 163 patients with complete 1-year clinical and echocardiographic follow-up, mean aortic valve gradient was 10 mmHg and all but 2 patients (1.2%) had trace to no prosthetic or paravalvular insufficiency. CONCLUSIONS: RAVR is safe and effective, providing the reproducible benefits of surgical AVR while affording a less invasive approach that permits the opportunity for concomitant procedures. For low and intermediate risk patients with aortic valve disease, RAVR is a potential reproducible alternative for patients and heart teams.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011