Comparison of clinical outcomes between robotic and thoracoscopic mitral valve repair
Shixiong Wei, Xin Zhang, Huimin Cui, Lin Zhang, Zhiyun Gong, Lianggang Li, Tong Ren, Changqing Gao, Shengli Jiang
- 发表年份
- 2020
- 引用次数
- 22
- 访问权限
- 开放获取
摘要
BACKGROUND: To compare the clinical outcomes and hospital cost of robotic versus thoracoscopic approaches to mitral valve plasty (MVP). METHODS: We retrospectively analyzed patients who received minimal invasive MVP between 2007 January and 2020 January at our department. The basic characteristics, echocardiography, surgical data, postoperative adverse events and hospital cost of the patients were collected. The primary outcomes of this study were direct hospital cost and 30-day outcomes, including the operative time, complications, and length of hospital stay. RESULTS: . $18,655.1±$2,558.3, all P<0.001). CONCLUSIONS: Both robotic and thoracoscopic approach for MVP are safe and reliable. Robotic technique has shorter operation time, while thoracoscopic technique has more advantages in blood transfusion rate, postoperative ventilation time, ICU duration and hospitalization expenses.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011