Adrenalectomy Performed with the Da Vinci Single-Port Robotic System: A Systematic Review and Pooled Analysis
Giuseppe Reitano, Arianna Tumminello, Carlo Prevato, Anna Cacco, Greta Gaggiato, G. Bau, Lorenzo Sabato, Elisa Tonet, Anna Gambarotto, Valerio Fusca, Ka Martina, Silvia Visentin, Giovanni Betto, Giacomo Novara, Fabrizio Moro, Fabio Zattoni
- Year
- 2025
- Citations
- 6
- Access
- Open access
Abstract
Introduction: The Da Vinci Single-Port (DV-SP) system emerged in 2018 but there is limited evidence on its use and perioperative outcomes for robot-assisted adrenalectomy (RAA). Methods: A systematic search was performed through PubMed, Scopus, Ovid, and WoS in December 2024. A PICO framework was used. Population: adult patients with adrenal masses; Intervention: DV-SP RAA; Outcomes: feasibility, reproducibility and safety of DV-SP RAA. A total of five retrospective studies involving 342 patients were included. The quantitative analysis was conducted using a random-effect model or a fixed-effect model as appropriate. A risk of bias assessment for non-randomized comparative studies and case series was performed. Results: The pooled mean operative time was 92.5 min (95% confidence interval [CI] 71.2, 113.9, p I2 = 0%, four studies), and the mean estimated blood loss (EBL) was 26.5 mL (95%CI −8.1, 61.2, I2 = 98.2%, three studies). Most of the procedures were completed with a single incision, though some required additional port placement, with a proportion of 9% (95%CI 0, 29, I2 = 71.7%, five studies). Perioperative complications were rare (0%, 95% CI 0, 4, I2 = 0%, five studies). Two studies comparing DV-SP and DV multi-port (MP) found no significant differences in complications. One study compared DV-SP RAA to DV Si or Xi single-access procedures. DV-SP showed improved operative techniques and better cosmetic outcomes. Limitations of this study are small sample size and potential selection bias due to smaller masses in the DV-SP RAA group. Conclusions: DV-SP RAA is a promising approach, offering reduced operative time, low EBL, and excellent cosmetic results. This study shows that DV-SP RAA seems reproducible, feasible, and safe. Limitation of the included studies are small sample size and selection bias, which limits the generalizability of the results. Randomized comparative studies between DV-SP and MP RAA are needed to further validate these findings.
Keywords
Related papers
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Fractional Differential Equations
Igor Podlubný
2025
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
Genetic Programming: On the Programming of Computers by Means of Natural Selection
John R. Koza
1992