Home /Research /Completely endoscopic removal of a dislocated Amplatzer atrial septal defect closure device
SURGICAL

Completely endoscopic removal of a dislocated Amplatzer atrial septal defect closure device

Johannes Bonatti, Nikolaos Bonaros, Silvana Müller, Thomas Bartel

Year
2007
Citations
9
Access
Open access

Abstract

Surgical treatment of residual shunts after transcatheter occlusion of atrial septal defect or patent foramen ovale is reported in approximately one to two percent of these percutaneous interventions. Minimally invasive surgery on the atrial septum is getting more and more common but little data is available on Amplatzer device explantation through limited access. No completely endoscopic device removal has been described previously. We report a case of a 57-year-old woman in whom an Amplatzer device was removed in a robotic totally endoscopic fashion through ports only using the daVinci telemanipulation system.

Keywords

MedicinePatent foramen ovalePercutaneousSurgeryOcclusionForamen secundum

Related papers

Browse all SURGICAL papers