Single-port robot-assisted abdominoperineal resection: a case review of the first four experiences
Moon Suk Choi, Seong Hyeon Yun, Jung Kyong Shin, Yoon Ah Park, Jung Wook Huh, Yong Beom Cho, Hee Cheol Kim, Woo Yong Lee
- Year
- 2021
- Citations
- 9
- Access
- Open access
Abstract
Recently, abdominoperineal resection (APR) using a robot has been demonstrated in other studies. However, there has been no report on APR for rectal cancer using the single-port robot (SPR) platform. In response to this research gap, we described the clinical experience of APR using a SPR. From April 2019 to March 2020, APR using a SPR platform was performed in a total of 4 patients. Three patients had a transumbilical approach, and 1 patient had a transstoma site approach. The average operation time was 307 minutes, and the patient docking time to the SPR platform was 133.5 minutes. There were no complications during the operation, and no laparoscopy or open conversion. No reoperation occurred within 30 days. Mild postoperative complications occurred in 2 patients. We found that APR has safety and feasibility in surgery using an SPR platform. There was no intraoperative event and severe postoperative complications.