In vitro ablation rates of Ho:YAG, p-Tm:YAG and TFL lasers
A. Quarà, A. Bravo-Balado, Stefano Moretto, A. Madden, Federico Zorzi, Letizia Maria Ippolita Jannello, S. Kutchukian, J. Cabrera, M. Corrales, M. Chicaud, Ugo Gradilone, Luigi Candela, C. Gorny, Frédéric Coste, Laurent Berthe, Steeve Doizi, Frédéric Panthier, Cristian Fiori, O. Traxer
- 发表年份
- 2025
- 引用次数
- 3
- 访问权限
- 开放获取
摘要
OBJECTIVE: This study compares the ablation rates of three laser systems-Holmium:YAG (Ho:YAG), Thulium Fiber Laser (TFL), and Pulsed Thulium:YAG (p-Tm:YAG)-for renal stone lithotripsy using a standardized robotic setup. MATERIALS AND METHODS: A robotic arm enabled consistent laser application on stone phantoms simulating calcium oxalate monohydrate (hard) and uric acid (soft) stones. Ablation efficiency (mm³/J) was assessed across different laser settings (0.2 J-50 Hz, 0.5 J-20 Hz, and 1.0 J-10 Hz) and fiber diameters (200 and 272 μm). Ablated volumes were quantified via micro-CT and 3D segmentation using 3DSlicer. Statistical analysis evaluated differences in performance. RESULTS: TFL demonstrated the highest ablation rates for both hard and soft stones, significantly outperforming Ho:YAG in multiple settings. For hard stones, TFL exhibited greater ablation efficiency than Ho:YAG, particularly at 0.5 J-20 Hz and 1.0 J-10 Hz. The p-Tm:YAG laser also outperformed Ho:YAG at 0.5 J-20 Hz. For soft stones, the difference between TFL and Tm:YAG was statistically significant at lower energy settings (0.20 J-50 Hz and 0.5 J-20 Hz). Compared to Ho:YAG, TFL showed significantly higher ablation rates across all tested settings (p < 0.05). The p-Tm:YAG laser showed intermediate performance, with higher efficiency than Ho:YAG but slightly lower than TFL. Fiber diameter influenced ablation, with 272 μm fibers yielding greater efficiency at lower energy settings (p < 0.05 at 0.20 J - 50 Hz and 0.5 J - 20 Hz for both stone types); this comparison was limited to p-Tm:YAG, as data for the other lasers are already available in the literature. CONCLUSION: TFL achieved the highest in vitro ablation efficiency. However, p-Tm:YAG represents a promising compromise, offering improved performance over Ho:YAG and a balanced profile between fragmentation and dusting capabilities.
关键词
相关论文
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Fractional Differential Equations
Igor Podlubný
2025
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
Genetic Programming: On the Programming of Computers by Means of Natural Selection
John R. Koza
1992