Green Tattoo Pre-Operative Renal Embolization for Robotic-Assisted and Laparoscopic Partial Nephrectomy: A Practical Proof of a New Technique
Eliodoro Faiella, Alessandro Calabrese, Domiziana Santucci, Riccardo Corti, Nicola Cionfoli, Claudio Pusceddu, Carlo de Felice, Giorgio Bozzini, Federica Mazzoleni, Rosa Maria Muraca, Lorenzo Paolo Moramarco, Massimo Venturini, Pietro Quaretti
- 发表年份
- 2022
- 引用次数
- 4
- 访问权限
- 开放获取
摘要
(1) Background: Our aim is to describe a new mixed indocyanine-non-adhesive liquid embolic agent (Onyx-18) pre-operative renal embolization technique for assisted-robotic and laparoscopic partial nephrectomy with near-infra-red fluorescence imaging. (2) Methods: Thirteen patients with biopsy-proven renal tumors underwent pre-operative mixed indocyanine-ethylene vinyl alcohol (EVOH) embolization (Green-embo) between June 2021 and August 2022. All pre-operative embolizations were performed with a super selective stop-flow technique using a balloon microcatheter to deliver an indocyanine-EVOH mixture into tertiary order arterial branch feeders and the intra-lesional vascular supply. Efficacy (evaluated as complete embolization, correct tumor mapping on infra-red fluorescence imaging and clamp-off surgery) and safety (evaluated as complication rate and functional outcomes) were primary goals. Clinical and pathological data were also collected. (3) Results: Two male and eleven female patients (mean age 72 years) received pre-operative Green-embo. The median tumor size was 29 mm (range 15-50 mm). Histopathology identified renal cell carcinoma (RCC) in 9 of the 13 (69%) patients, oncocytoma in 3 of the 13 (23%) patients and sarcomatoid RCC in 1 of the 13 (8%) patients. Lesions were equally distributed between polar, meso-renal, endo- and exophytic locations. Complete embolization was achieved in all the procedures. A correct green mapping was identified during all infra-red fluorescence imaging. All patients were discharged on the second day after the surgery. The median blood loss was 145 cc (10-300 cc). No significant differences were observed in serum creatinine levels before and after the embolization procedures. (4) Conclusions: The Green-tattoo technique based on a mixed indocyanine-non-adhesive liquid embolic agent (Onyx-18) is a safe and effective pre-operative embolization technique. The main advantages are the excellent lesion mapping for fluorescence imaging, reduction in surgical time, and definitive, complete and immediate tumor devascularization based on the deep Onyx-18 penetration, leading to a very low intra-operative blood loss.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011