The Accuracy and Clinical Success of Robotic-Assisted Total Knee Arthroplasty
Brian T. Nickel, Kaitlin M. Carroll, Andrew D. Pearle, Laura J. Kleeblad, Joost A. Burger, David J. Mayman, Geoffrey H. Westrich, Seth A. Jerabek
- 发表年份
- 2021
- 引用次数
- 8
- 访问权限
- 开放获取
摘要
Background: Robotic-assisted total knee arthroplasty (rTKA) has emerged as a patient-specific customizable tool that enables 3-dimensional preoperative planning, intraoperative adjustment, robotic-assisted bone preparation, and soft-tissue protection. Haptic rTKA may enhance component positioning, but only a few small studies have examined patient satisfaction and clinical outcomes after haptic rTKA. Purpose: In patients who underwent haptic rTKA, we sought to evaluate (1) the discrepancy in alignment between the executed surgical plan and implanted alignment in the coronal and sagittal planes 1 year postoperatively and (2) patient-reported outcomes 2 years postoperatively. Methods: From a prospectively collected database, we reviewed 105 patients who underwent haptic rTKA from August 2016 to May 2017. Two fellowship-trained arthroplasty surgeons independently reviewed hip-to-ankle standing biplanar radiographs to measure overall limb alignment and individual tibial and femoral component alignment relative to the mechanical axis and compared this to the executed surgical plan. Patient-reported outcomes were collected preoperatively and at 2 years postoperatively using the Lower Activity Extremity Score (LEAS), Knee Injury and Osteoarthritis Outcome Score Junior (KOOS Jr.), and Numeric Pain Rating Scale (NPRS). Results: Mean patient age was 62.4 years, and mean body mass index was 30.6 kg/m 2 . Interobserver reliability was significant with a κ of 0.89. Absolute mean deviations in postoperative coronal alignment compared to intraoperative alignment were 0.625° ± 0.70° and 0.45° ± 0.50° for the tibia and femur, respectively. Absolute mean deviations in postoperative tibial sagittal alignment were 0.47° ± 0.76°. Overall mechanical alignment was 0.97° ± 1.79°. Outcomes in LEAS, KOOS Jr., and NPRS changed from 8 to 10, 78 to 88.3, and 8 to 1, respectively. Conclusions: Haptic rTKA demonstrated high reliability and accuracy (less than 1°) of tibial coronal, femoral coronal, and tibial sagittal component alignment postoperatively compared to the surgical plan. Patient-reported outcomes improved, as well. A more rigorous study on long-term outcomes is warranted.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011