首页 /研究 /Robotic Transcatheter Mitral Valve Replacement Using the Sapien XT in the Setting of Severe Mitral Annular Calcification
SURGICAL

Robotic Transcatheter Mitral Valve Replacement Using the Sapien XT in the Setting of Severe Mitral Annular Calcification

Michael S. Koeckert, Didier F. Loulmet, Mathew Williams, Peter J. Neuburger, Eugene A. Grossi

发表年份
2016
引用次数
9

摘要

We describe the use of the Sapien XT, placed in the mitral position using a totally endoscopic robotic approach in a 76-year-old man with extensive circumferential mitral calcifications and severe stenosis. The patient was at high risk for traditional open surgery and a large mitral valve annulus prevented safe transcatheter deployment due to size mismatch. Our novel approach offered a minimally invasive technique for native mitral valve replacement in a high-risk patient with anatomical constraints prohibitive to conventional approaches. doi: 10.1111/jocs.12737 (J Card Surg 2016;31:303-305).

关键词

MedicineMitral valve replacementStenosisCalcificationMitral valveCardiologyInternal medicineMitral annulusCalcinosisRadiology

相关论文