Patients’ and Physicians’ Knowledge of Radiation Exposure Related to Spine Surgery
Michelle C. Scott, Anoop R. Galivanche, Elbert J. Mets, Neil Pathak, Joseph B. Kahan, Patrick J. Burroughs, Arya G. Varthi, Lee E. Rubin, Jonathan N. Grauer
- 发表年份
- 2020
- 引用次数
- 11
摘要
STUDY DESIGN: Cross-sectional survey. OBJECTIVE: Examine patients' and physicians' estimates of radiation exposure related to spine surgery. SUMMARY OF BACKGROUND DATA: Patients are commonly exposed to radiation when undergoing spine surgery. Previous studies suggest that patients and physicians have limited knowledge about radiation exposure in the outpatient setting. This has not been assessed for intraoperative imaging. METHODS: A questionnaire was developed to assess awareness/knowledge of radiation exposure in outpatient and intraoperative spine care settings. Patients and surgeons estimated chest radiograph (CXR) equivalent radiation from: cervical and lumbar radiographs (anterior-posterior [AP] and lateral), computed tomography (CT), magnetic resonance imaging (MRI), intraoperative fluoroscopy, and intraoperative CT (O-arm). Results were compared to literature-reported radiation doses. RESULTS: Overall, 100 patients and 26 providers completed the survey. Only 31% of patients were informed about outpatient radiation exposure, and only 23% of those who had undergone spine surgery had been informed about intraoperative radiation exposure. For lumbar radiographs, patients and surgeons underestimated CXR-equivalent radiation exposures: AP by five-fold (P < 0.0001) and seven-fold (P < 0.0001), respectively, and lateral by three-fold (P < 0.0001) and four-fold (P = 0.0002), respectively. For cervical CT imaging, patients and surgeons underestimated radiation exposure by 18-fold (P < 0.0001) and two-fold (P = 0.0339), respectively. For lumbar CT imaging, patients and surgeons underestimated radiation exposure by 31-fold (P < 0.0001) and three-fold (P = 0.0001), respectively. For intraoperative specific cervical and lumbar imaging, patients underestimated radiation exposure for O-arm by 11-fold (P < 0.0001) and 22-fold (P = 0.0002), respectively. Surgeons underestimated radiation exposure of lumbar O-arm by three-fold (P = 0.0227). CONCLUSION: This study evaluated patient and physician knowledge of radiation exposure related to spine procedures. Underestimation of radiation exposure in the outpatient setting was consistent with prior study findings. The significant underestimation of intraoperative cross-sectional imaging (O-arm) is notable and needs attention in the era of increased use of such technology for imaging, navigation, and robotic spine surgery. LEVEL OF EVIDENCE: 4.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011