Comparison of an Er: YAG laser osteotome versus a conventional drill for the use in osteo‐ odonto‐keratoprosthesis (OOKP)
Britt-Isabelle Berg, Michael Peyer, Lorenz Kuske, Marcello Augello, Andreas Schötzau, Markus Steineck, Waldemar Deibel, Daniel Mathys, Philipp Jürgens, Christoph Kunz, David Goldblum
- 发表年份
- 2019
- 引用次数
- 14
摘要
OBJECTIVES: The osteo-odonto-kerato-prosthesis (OOKP) procedure is a complex, multi-stage, multidisciplinary surgical intervention for the treatment of severe corneal blindness. One step of the OOKP consists of creating a precise hole into a tooth in which an optic cylinder is subsequently inserted; its shape must ensure a perfect watertight fit. The Er: YAG laser (L) used in this study is part of CARLO®, the first laser osteotome that enables surgical planning based on computed tomography data, robot guidance, and a precise execution of laser cuts in teeth and bone tissue, using laser photoablation rather than conventional mechanical methods. The purpose of this study was to assess whether the Er: YAG laser is non-inferior compared to a conventional drill. METHODS: Thirty-two bovine incisors were grounded to a thickness of 1.5 mm. In 16 teeth, a 3.5 mm hole was drilled progressively into each tooth, using dental burs (B) of increasing diameter that were attached to a fixed drill machine. In the other 16 teeth, a hole was created using an Er: YAG laser at a wavelength of 2.94 µm (Part of CARLO®). In seven teeth of each group, the cylinder was inserted and fixated with polymethylmethacrylate (PMMA) bone cement. In the remaining seven teeth of each group, the cylinder was inserted without fixation material (press-fit). After bonding and drying, all specimens were stored in water until force measurements were recorded using a uniaxial traction machine. The force required to move the optical cylinder out of the hole in the tooth was measured using an Instron 3344 testing system. Scanning electron microscope (SEM) and light microscope (LM) visualization of the holes created with the laser and the drill were performed in two teeth (SEM)/four teeth (LM) per method. RESULTS: Significant differences (P < 0.001) were found for the following parameters: B PMMA versus B press-fit; B PMMA versus L press-fit; L PMMA versus B press-fit; L PMMA-L press-fit. This shows that PMMA bone cement fixation is superior to press-fit. No significant differences were found between B PMMA-L PMMA (P = 0.93) and B press-fit-L press-fit (P = 0.83). The SEM pictures showed a smoother surface using L. CONCLUSIONS: The laser cut holes were as strong as bur-drilled holes, although SEM pictures showed a smoother surface of the laser cut holes. Hence, laser osteotomes open the possibility to custom fit the hole exactly to the width of the cylinder, which represents a potential advantage of the laser over the conventional bur. Lasers Surg. Med. 51:531-537, 2019. © 2019 Wiley Periodicals, Inc.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Darren J. Lipomi, Michael Vosgueritchian, Benjamin C. K. Tee 等 7 位作者
2011
Stretchable, Skin‐Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Morteza Amjadi, Ki‐Uk Kyung, Inkyu Park 等 4 位作者
2016
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012