Retrospective Review on Accuracy: A Pilot Study of Robotically Guided Thoracolumbar/Sacral Pedicle Screws Versus Fluoroscopy-Guided and Computerized Tomography Stealth-Guided Screws
Brian Fiani, Syed A. Quadri, Vivek Ramakrishnan, Blake Berman, Yasir Khan, Javed Siddiqi
- 发表年份
- 2017
- 引用次数
- 15
- 访问权限
- 开放获取
摘要
Introduction Pedicle screw insertion is the mainstay of thora-cic and lumbosacral posterior spinal instrumentation. However, it may be associated with complications such as screw mal-positioning. The purpose of this study was to develop a pilot study to compare the accuracy of robot-guided screw insertion versus hand-guided screw placement for spinal instrumentation. The hand-guided screws were placed with assistance from computerized tomography (CT) stealth guidance or fluoroscopy. Materials and methods A retrospective analysis of medical records was done for all patients that had pedicle screw insertion for instrumentation between the dates of December 2013 and January 2016 with post-screw placement CT imaging. The analysis was conducted on screw accuracy between the two categories based on the Gertzbein-Robbins classification. Results A total of 49 screws were analyzed for accuracy in six patients. There was no statistically significant difference between the accuracy of hand-placed pedicle screws versus the robotically placed screws (p = 0.311). There was no statistically significant difference in blood loss (p = 0.616), length of procedure (p = 0.192), or post-operative length of stay (p = 0.587). Conclusion The findings of our pilot study agree with most prior studies that there was no statistically significant difference in the accuracy of pedicle screw placement between the two methods of screw placement. Therefore, the techniques are equivocal in accuracy. The new technology (robotic-guidance) is as safe as conventional techniques for screw placement. Just like in any surgery, the technique preference should remain surgeon dependent. The results are only from a small sample size in the development of a pilot study so a strong reliance on the data would not be suggested. The study was a preliminary study that will be used as a template and learning process to create a future prospective study to investigate CT stealth and robotically guided screw placement versus "free hand" guided screws.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011