首页 /研究 /Trocar site hernia on an 8-mm port following robotic-assisted hysterectomy
SURGICAL

Trocar site hernia on an 8-mm port following robotic-assisted hysterectomy

Gökhan S. Kılıç, Tevfik Berk Bıldacı, Ömer Lütfi Tapısız, İbrahim Alanbay, Teresa M. Walsh, Olga Swanson

发表年份
2013
引用次数
19

摘要

The increasing use of laparoscopy has resulted in added complications specific to the laparoscopic approach, such as trocar site hernia (TSH), which is an uncommon but well-recognized problem for both regular laparoscopic and robotic-assisted laparoscopic procedures. We describe an extremely rare case of TSH at an 8-mm port site occurring a relatively short time after surgery in a 53-year-old patient undergoing robotic-assisted laparoscopic hysterectomy for benign reasons. Additionally, this report attempts to explain the possible etiological factors relating to TSH following robotic-assisted surgery. According to our case report, a defect in the 8-mm port that may lead to hernia is one possible explanation, and closure of the 8-mm trocar sites' fascia may be a safer approach during robotic-assisted surgery. Additional reports are needed to accurately determine the frequency of occurrence and importance of this complication.

关键词

MedicineRobotic surgeryLaparoscopySurgeryPort (circuit theory)General surgeryHerniaHysterectomyLaparoscopic surgeryFascia

相关论文