Computer‐assisted surgery and patient‐specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta‐analysis
Reha N. Tandoğan, Nanne P. Kort, Ersin Erçin, Floris van Rooij, Luca Nover, Mo Saffarini, Michael T. Hirschmann, Roland Becker, David Dejour, Michael Liebensteiner, Jacobus H. Müller, Antonia F. Chen, René El Attal, Markus Arnold
- 发表年份
- 2021
- 引用次数
- 30
摘要
PURPOSE: To determine whether patient-specific instrumentation (PSI), computer-assisted surgery (CAS) or robot-assisted surgery (RAS) enable more accurate rotational alignment of the tibial baseplate in primary total knee arthroplasty (TKA) compared to conventional instrumentation, in terms of deviation from the planned target and the proportion of outliers from the target zone. METHODS: The authors independently conducted three structured electronic literature searches using the PubMed, Embase®, and Cochrane Central Register of Controlled Trials databases from 2007 to 2020. Studies were included if they compared rotational alignment of the tibial baseplate during TKA using conventional instrumentation versus PSI, CAS, and/or RAS, and reported deviation from preoperatively planned rotational alignment of the tibial baseplate in terms of absolute angles and/or number of outliers. Methodological quality of eligible studies was assessed by two researchers according to the Downs and Black Quality Checklist for Health Care Intervention Studies. RESULTS: Fifteen studies, that reported on 2925 knees, were eligible for this systematic review, of which 6 studies used PSI, and 9 used CAS. No studies were found for RAS. Of the studies that reported on angular deviation from preoperatively planned rotational alignment, most found smaller deviations using PSI (0.5° to 1.4°) compared to conventional instrumentation (1.0° to 1.6°). All studies that reported on proportions of outliers from a target zone (± 3°), found lower rates of outliers using PSI (0 to 22%) compared to conventional instrumentation (5 to 96%). Most studies reported smaller angular deviation from preoperatively planned rotational alignment using CAS (0.1° to 6.9°) compared to conventional instrumentation (1.1° to 7.8°). Of the studies that reported on proportions of outliers from a target zone (± 3°), most found fewer outliers using CAS (10 to 61%) compared to conventional instrumentation (17 to 78%). CONCLUSION: This systematic review and meta-analysis revealed that both CAS and PSI can improve the accuracy of rotational alignment of the tibial baseplate by decreasing angular deviation from the preoperatively planned target and reducing the proportion of outliers from the target zone. The clinical relevance is that PSI and CAS can improve alignment, though the thresholds necessary to grant better outcomes and survival remain unclear. LEVEL OF EVIDENCE: IV.
关键词
相关论文
Self-Organizing Maps
Teuvo Kohonen
1995
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012