首页 /研究 /Exoskeleton transparency: feed-forward compensation vs. disturbance observer
HRI

Exoskeleton transparency: feed-forward compensation vs. disturbance observer

Fabian Just, Özhan Özen, Philipp Bösch, Hanna Bobrovsky, Verena Klamroth-Marganska, Robert Riener, Georg Rauter

发表年份
2018
引用次数
50

摘要

Abstract Undesired forces during human-robot interaction limit training effectiveness with rehabilitation robots. Thus, avoiding such undesired forces by improved mechanics, sensorics, kinematics, and controllers are the way to increase exoskeleton transparency. In this paper, the arm therapy exoskeleton ARMin IV+ was used to compare the differences in transparency offered by using the previous feed-forward model-based controller, with a disturbance observer in a study. Systematic analysis of velocity-dependent effects of controller transparency in single- and multi-joint scenarios performed in this study highlight the advantage of using disturbance observers for obtaining consistent transparency behavior at different velocities in single-joint and multi-joint movements. As the main result, the concept of the disturbance observer sets a new benchmark for ARMin transparency.

关键词

Transparency (behavior)ExoskeletonControl theory (sociology)Disturbance (geology)KinematicsRobotControl engineeringComputer scienceBenchmark (surveying)Observer (physics)

相关论文

查看 HRI 分类全部论文