Improved protocol for measurement of plasma β‐amyloid in longitudinal evaluation of Alzheimer's Disease Neuroimaging Initiative study patients
Michal Figurski, Teresa Waligórska, Jon B. Toledo, Hugo Vanderstichele, Magdalena Korecka, Virginia M.‐Y. Lee, John Q. Trojanowski, Leslie M. Shaw
- 发表年份
- 2012
- 引用次数
- 62
摘要
BACKGROUND: The interassay variability and inconsistency of plasma β-amyloid (Aβ) measurements among centers are major factors precluding the interpretation of results and a substantial obstacle in the meta-analysis across studies of this biomarker. The goal of this investigation was to address these problems by improving the performance of the bioanalytical method. METHODS: We used the Luminex immunoassay platform with a multiplex microsphere-based reagent kit from Innogenetics. A robotic pipetting system was used to perform crucial steps of the procedure. The performance of this method was evaluated using two kit control samples and two quality control plasma samples from volunteer donors, and by retesting previously assayed patient samples in each run. This setup was applied to process 2454 patient plasma samples from the Alzheimer's Disease Neuroimaging Initiative study biofluid repository. We have additionally evaluated the correlations between our results and cerebrospinal fluid (CSF) biomarker data using mixed-effects modeling. RESULTS: The average precision values of the kit controls were 8.3% for Aβ(1-40) and 4.0% for Aβ(1-42), whereas the values for the plasma quality controls were 6.4% for Aβ(1-40) and 4.8% for Aβ(1-42). From the test-retest evaluation, the average precision was 7.2% for Aβ(1-40) and 4.5% for Aβ(1-42). The range of final plasma results for Alzheimer's Disease Neuroimaging Initiative patients was 13 to 372 pg/mL (median: 164 pg/mL) for Aβ(1-40) and 3.5 to 103 pg/mL (median: 39.3 pg/mL) for Aβ(1-42). We found that sample collection parameters (blood volume and time to freeze) have a small, but significant, influence on the result. No significant difference was found between plasma Aβ levels for patients with Alzheimer's disease and healthy control subjects. We have determined multiple significant correlations of plasma Aβ(1-42) levels with CSF biomarkers. The relatively strongest, although modest, correlation was found between plasma Aβ(1-42) levels and CSF p-tau(181)/Aβ(1-42) ratio in patients with mild cognitive impairment. Plasma Aβ(1-40) correlations with CSF biomarkers were weaker and diminished completely when we used longitudinal data. No significant correlations were found for the plasma Aβ(1-42)/Aβ(1-40) ratio. CONCLUSIONS: The precision of our robotized method represents a substantial improvement over results reported in the literature. Multiple significant correlations between plasma and CSF biomarkers were found. Although these correlations are not strong enough to support the use of plasma Aβ measurement as a diagnostic screening test, plasma Aβ(1-42) levels are well suited for use as a pharmacodynamic marker.
关键词
相关论文
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Fractional Differential Equations
Igor Podlubný
2025
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
Genetic Programming: On the Programming of Computers by Means of Natural Selection
John R. Koza
1992