首页 /研究 /Accuracy of Robot-Assisted Placement of Lumbar and Sacral Pedicle Screws
SURGICAL

Accuracy of Robot-Assisted Placement of Lumbar and Sacral Pedicle Screws

Florian Ringel, Carsten Stüer, Andreas Reinke, Alexander Preuß, Michaël Behr, Florian Auer, Michael Stoffel, Bernhard Meyer

发表年份
2012
引用次数
349

摘要

In Brief Study Design. Single-center prospective randomized controlled study. Objective. To evaluate the accuracy of robot-assisted (RO) implantation of lumbar/sacral pedicle screws in comparison with the freehand (FH) conventional technique. Summary of Background Data. SpineAssist is a miniature robot for the implantation of thoracic, lumbar, and sacral pedicle screws. The system, studied in cadaver and cohort studies, revealed a high accuracy, so far. A direct comparison of the robot assistance with the FH technique is missing. Methods. Patients requiring mono- or bisegmental lumbar or lumbosacral stabilization were randomized in a 1:1 ratio to FH or RO pedicle screw implantation. Instrumentation was performed using fluoroscopic guidance (FH) or robot assistance. The primary end point screw position was assessed by a postoperative computed tomography, and screw position was classified (A: no cortical violation; B: cortical breach <2 mm; C: ≥2 mm to <4 mm; D: ≥4 mm to <6 mm; E: ≥6 mm). Secondary end points as radiation exposure, duration of surgery/planning, and hospital stay were assessed. Results. A total of 298 pedicle screws were implanted in 60 patients (FH, 152; RO, 146). Ninety-three percent had good positions (A or B) in FH, and 85% in RO. Preparation time in the operating room (OR), overall OR time, and intraoperative radiation time were not different for both groups. Surgical time for screw placement was significantly shorter for FH (84 minutes) than for RO (95 minutes). Ten RO screws required an intraoperative conversion to the FH. One FH screw needed a secondary revision. Conclusion. In this study, the accuracy of the conventional FH technique was superior to the RO technique. Most malpositioned screws of the RO group showed a lateral deviation. Attachment of the robot to the spine seems a vulnerable aspect potentially leading to screw malposition as well as slipping of the implantation cannula at the screw entrance point. This study evaluated the accuracy of lumbar and sacral pedicle screw implantation by a robot-assisted technique compared with the conventional freehand approach. In this study, the freehand technique proved to be superior to the robot-assisted technique with regard to screw implantation accuracy. Although the miniature robot per se is believed to provide good accuracy, several other technical aspects could explain the inferior accuracy.Florian Ringel, Carsten Stüer, Andreas Reinke, Alexander Preuss, Michael Behr, Florian Auer, Michael Stoffel, and Bernhard Meyer

关键词

MedicineLumbosacral jointLumbarSurgeryNuclear medicineCadaver

相关论文

查看 SURGICAL 分类全部论文