首页 /研究 /Automatic navigation of an untethered device in the artery of a living animal using a conventional clinical magnetic resonance imaging system
OTHER

Automatic navigation of an untethered device in the artery of a living animal using a conventional clinical magnetic resonance imaging system

Sylvain Martel, Jean‐Baptiste Mathieu, Ouajdi Felfoul, Arnaud Chanu, Eric Aboussouan, Samer Tamaz, Pierre Pouponneau, L’Hocine Yahia, Gilles Beaudoin, Gilles Soulez, Martin Mankiewicz

发表年份
2007
引用次数
355

摘要

The feasibility for in vivo navigation of untethered devices or robots is demonstrated with the control and tracking of a 1.5mm diameter ferromagnetic bead in the carotid artery of a living swine using a clinical magnetic resonance imaging (MRI) platform. Navigation is achieved by inducing displacement forces from the three orthogonal slice selection and signal encoding gradient coils of a standard MRI system. The proposed method performs automatic tracking, propulsion, and computer control sequences at a sufficient rate to allow navigation along preplanned paths in the blood circulatory system. This technique expands the range of applications in MRI-based interventions.

关键词

Magnetic resonance imagingNuclear magnetic resonanceMaterials scienceBiomedical engineeringComputer scienceMedicineRadiologyPhysics