首页 /研究 /A mixed Hinfty-Passivity approach for Leveraging District Heating Systems as Frequency Ancillary Service in Electric Power Systems
OTHER

A mixed Hinfty-Passivity approach for Leveraging District Heating Systems as Frequency Ancillary Service in Electric Power Systems

Xinyi Yi, Ioannis Lestas

发表年份
2026
访问权限
开放获取

摘要

This paper introduces a mixed H-infinity-passivity framework that enables district heating systems (DHSs) with heat pumps to support electric-grid frequency regulation. The analysis illustrates how the DHS regulator influences coupled electro-thermal frequency dynamics and provides LMI conditions for efficient controller design. We also present a disturbance-independent temperature regulator that ensures stability and robustness against heat-demand uncertainty. Simulations demonstrate improved frequency-control dynamics in the electrical power grid while maintaining good thermal performance in the DHS.

关键词

eess.SYstat.APstat.ME

相关论文